Thursday, March 22, 2012

base Causes For Residential construction Failures

A/Overview

This document has been written to give clients of asset safe an understanding of the most tasteless types of building defects that can be found in structure whilst doing an As 4349.1 inspection. This list gives the reader a basic shape of the more tasteless defects and the reader should be aware that there are actually thousands of forms of building defects. The items which we have listed are the more tasteless ones only.

Stainless Steel French Door Refrigerator

B/Abstract

The narrative lists some of the more tasteless residential building failures together with the causes based on the case studies carried out by the writer as a licensed Builder. The writer has also included some of the causes of the failures.

Purpose
The purpose of this narrative is to give the reader a overview of the types of residential building failures and the suggested remedies to these defects.

Method
This narrative is presented as a case study based on the caress and personal records of the author over the last 15 years as a licensed Builder.

Findings
A large proportion of structural building failures listed in this narrative have in my view been caused by the mismanagement of stormwater colse to houses leading to movement in the homes. The remainder of the failures are caused by poor building practices and or poor maintenance.

C/Introduction

The most tasteless forms of building failure noted during As 4349.1 house inspections by the writer in Adelaide are as follows.

Slab Edge wetting
This is the horizontal ingress of moisture and salts in clarification from the soil which enter into footing edges straight through the capillary activity (Suction caused by the concrete) of the concrete. It is caused by a estimate of factors including, Concretors pushing down the Fortecon membrane with edge forms prior to pouring a floor slab, relatively poor cement concrete in the footing (Many engineers have called for 32 Mpa concrete to resist the ingress of salts in lieu of 20 to 25 Mpa currently used), Concrete over pours caused when concretors edge forms are not settled low adequate to stop a horizontal over pour which can lead to water ponding on the top face of the over pour creating a pool of water. The final cause is the lack of a plastic membrane to be settled in the middle of the paving and the footing edge.

The damage that can be caused though this question includes, mould and rotting to the underside of floor coverings internally and the fretting of the concrete straight through the salt attacking the cement matrix straight through a hydraulic activity both internally and externally. (Salt crystals advance inside the concrete matrix thereby causing it to fret and crack).

Rising Damp in walls
This is a similar question to Salt damp detailed below. The main dissimilarity is that Salt damp is commonly a 90 to 100% break down of the Damp procedure in the wall whilst rising dampness is a partial failure of the Damp procedure and the partial failure commonly means that the damage to the masonry wall is not as bad as Salt damp. There is a good occasion that rising dampness may be found in most pre 1950 homes and the Rising dampness could be dinky to erosion of the mortar joints by as dinky as 1 to 2 mm from its customary face. The treatment is the same is Salt damp.

The client should be aware however that in most cases the rising dampness is not treated as the erosion of the masonry is very slow and it may have taken 50 years for the mortar to erode 4mm deep from the face of the brickwork. I would recommend clients to monitor this if the damage is not major.

Salt Damp in Walls
This is caused straight through the vertical ingress of moisture and salts into a wall which can lead to the wall fretting and not being able to take structural loads. The damage caused to the masonry is from the salt crystals inside the masonry addition leading to the bricks and or mortar fretting. In some cases the salt damp can render the masonry unstable.

It is caused by a estimate of factors together with the full breakdown of the damp procedure (Pre 1910 homes had pitch or bitumen in the middle of the footing and bricks and this becomes fragile with age), paving and or render bridging the damp procedure also causes this.

Breacher piece failures in showers This is where the breacher piece fails straight through metal fatigue via thousands of heat cycles inside the wall (This is where the hot and cold water meet inside the wall in the shower). Water then flows into the walls. commonly a breacher piece will fail in a shower every 25 to 30 years or so and it is quite common. A tell tale sign of a breacher which has been substituted is two off different tiles to the walls of the shower.

During inspections carried out by asset safe the business carries out a explore of the wet area walls in its selected narrative using an electronic moisture meter to recognize this defect. High moisture levels to the walls next to the shower commonly indicate that it is leaking.

Brick increase
Cracks in walls Older homes can have brick increase cracks which regularly occur at the end of a wall in a vertical plane. Clay bricks will actually advance as they are porous. If a house does not have control joints in the wall the bricks can exert a compression load on one an additional one leading to cracking.

Terracotta roof tiles
Fired clay roof tiles will fret when exposed to moisture for long periods of time and this commonly occurs at the laps of the tiles. The tiles can also fret in seaside environments due to salt attacking the tiles. It is not uncommon to see these roof tiles fretting to the laps on the underside of the roof tiles. As these tiles age they can also become very fragile and are actually cracked.

In most instances when the tiles are fretting they will need replacing within the short term. Concrete cancer in footings and precast concrete lintels. This occurs when the steel bars inside the concrete rust due to moisture/salt/Carbonation ingress into the concrete. As the bars rust they advance causing the concrete to crack. This can cause cracking in the surrounding concrete elements. The client should be aware that it is very high-priced to mend this defect.

Tree damage
Although some tree roots can cause hydraulic damage from the roots physically intriguing the building element, most building failures are caused by the tree withdrawing moisture from the soil. This then leads to the soil contracting which can cause building elements to drop or move.

In a large estimate of inspections over the years the writer has observed walls and footings dropping or intriguing due to soil contraction when a tree is too close to the base of a wall. In most instances the writer would recommend clients to keep large trees well away from the house. If this is not potential an impermeable root fabric can be used to stop the tree roots growing under a house.

Stormwater damage and Soil movement
This is caused when gutters, stormwater pipes and downpipes overflow/leak causing the soil colse to and under the footing to be saturated. Once the soil becomes saturated it then loses its capability to take load and the soil can collapse leading to the building element dropping or moving. In some instances reactive soils can advance also leading to cracking. This then places uplifting loads on a house which can lead to vital cracking and movement as well.

In Adelaide reactive (fine soils such as clays) can be found at the base of the foothills where fine silts run off the hills. The fine reactive soils can commonly be found in Rostrevor, Athelstone and Campbelltown.

Lack of Paving colse to the external perimeter. This can cause expansion and contraction in the soil colse to the footing leading to movement in the Building. Ie Expansion in soil after heavy rains and contraction in the soil in the summer. In some instances the contraction of the soil under the footing (on the external portion) can lead to the footing rotating on the external side as it drops. The author has seen many instances of this occurring and this leads to the whole wall leaning out or in. (Bows out at the base and then leans in at the top). In these instances the wall commonly needs to be pulled down and rebuilt.

In many of the asset safe reports you may see a note detailing seal gaps at the footing paving junction. Many houses inspected by this business have gaps at this junction and this can allow moisture to enter both under the house and also under the paving. Where the water enters under both elements it can erode the soil away and or cause the soil to whether advance or contract. In this instance the gap should be sealed off with a flexible sealant.

Older style wiring.
The author has seen electrical failures from the following during inspections over the years., -Canvas coated and vulcanised rubber power cables. In the first instance the canvas can be eaten by rodents or just physically ages leading to the cables being exposed which can corollary in fires. The same can happen with older rubber cables which can split.

-Power cables not in conduit in caress with steel frames. I.e. If the cables are damaged the frame becomes live. A estimate of houses over the years have been inspected by asset safe and found to have new wiring in all areas of the house but not inside the existing hard plaster. during the selected house inspections this business uses a high powered torch to recognize wall patches and chases to the walls. An existing house without wall chases above the light switches and power points would commonly indicate that the customary wiring has not been removed. In this instance asset safe would recommend the client to engage an electrician to carry out a explore of the house to confirm if the wiring is customary to these areas. Hard plaster cannot be removed during a house inspection as the seller would not commonly approve this.

Leaking pipes in wet areas This is commonly caused straight through corrosion of lead or galvanised steel waste pipes under or in floor slabs. As the pipes corrode this leads to a leak which can wash away sub fill in a floor leading to the floor and or footing dropping.

This is very high-priced to mend as commonly the pipes are cast into the floor slabs in the wet areas and they need to be jack hammered up. This is a tasteless flaw as a large estimate of houses in pre 1970 properties have galvanised steel pipes cast into the floor slabs. For these steel pipes it is not a matter of if but when the pipes need to be substituted . Having stated this steel pipes although not draining as well as they should do can function for many years until funds can be found to replace them.

If you have steel waste and or water furnish pipes in a pre 1970 house and you are contemplating a wet area renovation with new tiles etc we would strongly recommend you to remove the steel pipes prior to the renovation.ie If you renovate the wet areas without removing the steel pipes a failure of the pipes could corollary in you having to re renovate the wet area at great cost again!

Cracks/Movement in walls
Movement in any home is hard to control. In most instances cracks are caused by changes in soil moisture levels colse to the footing although trees can also cause vital movement. Horizontal cracks can occur in walls if a window lintel sags or if a footing/wall drops.

Diagonal cracks radiating away from window and or door heads are the most tasteless form of cracks. Lateral movement cracks can occur with a shear load if a footing rotates (Drops) on one side. Due to Adelaide's dry atmosphere soil shrinkage linked cracking in homes is causing many problems. This leads to footing village (Dropping of the footing) and cracks in all building elements.

Roof frame failures
The first type of failure is for an older style roof which does not have under purlins and or struts. In this instance the failure is commonly from the frame not being able to take the dead loads from the weight of roof tiles. It is tasteless to see the frame sag heavily and split and this instance repairs may need to be carried out. If a roof frame is sagging from the weight of the roof tiles and the timber frame is not splitting or showing any signs of stress our advice to you is to intimately monitor the roof frame.

In the second instance the writer has seen heavy splitting to timber colse to defective gang nail trusses manufactured in the 1970's. In some instances the trusses could not take roof loads and sagged.

White ant assault
Property safe does not carry out a explore for white ants in our inspections and we would recommend that you engage a pest controller to do this. White ant assault is a very tasteless question in structure with the ants actually eating any form of timber in a home. As the timber wall frame is load bearing in a brick veneer home this can led to structural failures. The ants will regularly enter a home where voids are close to the ground. One example of an entry point is where the paving bridges the Damp procedure allowing ants to enter a wall cavity straight through weep holes (i.e. The paving is poured above the Damp procedure in the wall).

A second example is where garden beds are settled up against walls without any paving and in this instance we would recommend on removing the garden bed and then installing paving all colse to the house.

Poor Workmanship
The following defects are caused by poor workmanship which does not comply with the building Code. -Render in brick wall weep holes This stops condensation from draining out of a cavity. The writer has seen fretting render caused by blocked weep holes. -Bricks overhanging the footing. Bca allows a tolerance but in many instances concreters' set out the slab incorrectly. As the wall is not supported the bricks can bow out.

-Render bridging wall Damp Courses In many instances plasterers do not assault a horizontal line straight through render which can corollary in ground moisture and salts rising up into the wall by passing the Damp Course. This can cause Salt damp in a wall.

-Concrete slabs poured up against brickwork. In some instances colse to porch slabs builders sometimes place the Damp procedure one brick procedure above the footing and pour the porch slab up against the first procedure of clay bricks. In this situation clay bricks are not designed to be exposed to ground moisture and salts for extended periods of time and this leads to fretting of the bricks.

This is sometimes seen in older houses and it is hard to fix this if the fretting of the walls is heavy. Field to a site visit sometimes the best selection in this instance is to jackhammer up the floor slab and then repour the concrete below the Damp Course. At the end of the day this is an high-priced question to rectify. The writer has seen this in many garages in pre 1980 houses.

-Puddle flanges to wet areas not installed correctly. Puddle flanges are designed to drain any water caught in the middle of the waterproof membrane and the floor tiles. In some instances the flanges are laid proud of the floor and the trapped water cannot drain into the waste pipe. In a second floor building this ponding water can bypass the membrane leading to the timber floor swelling and door, wall and window frames jamming up from compression loads. If this has occurred it is very high-priced to repair.

-Waterproof membranes to showers This is probably the largest of the observed failures mentioned in this narrative in my opinion. If a shower leaks this can cause heavy damage to the timber wall frame via wood rot and water damage. In masonry wall long term moisture leaks into the surrounding walls can lead to fretting of the masonry brick walls and render. In a metal wall frame heavy rusting can occur.

In a timber wall frame long term leaks into the shower walls can also cause swelling of the wall cladding and wall tiles debonding and cracking. In a masonry wall the high moisture levels can lead to the tiles cracking and or debonding off the walls.

The Bca (Building Code) requires silicone to the internal wall corners of a shower and many tilers still grout these areas which leads to cracking as the grout is rigid. The Bca also requires an angle to be installed at the wall floor junction in the shower and in many instances this is not installed.

Many waterproof membranes are not installed correctly or the wrong materials are used.ie Bitumen membranes to showers which leach into the grout, liquid membranes not reinforced with polypropylene gauze fabrics. Etc.

Asbestos
Most homes built before 1988 would have some cement asbestos based cladding in the house. asset safe can carry out a explore to recognize this based on our view only in our selected report. This can only be verified by analysing samples under a microscope in a laboratory so any explore is based on our view only and would need to be confirmed by the Lab. Our selected narrative does not analyse the samples in a Laboratory.

If this material is disturbed by grinding, drilling or cutting it can be fatal. Areas where it can be found in a house include.

-Backing sheet for the power board -Old floor coverings -Eaves cladding externally. -Wet area cladding Etc.

D/Discussion

In terms of the remedies to the failures identified above these are as follows.

Slab edge wetting
This can quite actually be solved by stopping the replacement of moisture horizontally into the slab by placing an impervious membrane in the middle of the paving and the footing or directly onto the full depth of the footing. Plastic, waterproof membranes (Liquid or sheet) are the best remedies.

Salt damp
This can be repaired by forming a new Damp procedure by undersetting (removing bricks and inserting a new plastic membrane) or chemical injection (Silane siloxane injection) where the Damp procedure has failed. Where the paving bridges the damp procedure the paving should be lowered. If render bridges the Damp procedure the render can be removed.

Breacher piece failures
In this instance commonly four off wall tiles, the affected render and the customary fitting are removed. The reverse is then carried out with new materials.

Brick increase cracks
This form of cracking can be stopped by forming control joints in the wall above the windows and doors to allow the bricks to advance from long term moisture absorption.

Terracotta roof tiles
Generally if these tiles are fretting at the laps they should be removed and then substituted with new concrete roof tiles or metal roof cladding.

Concrete Cancer
The only way that this can be repaired is by physically removing the affected concrete fully exposing 360 Degrees of the bar, placing saw cuts , grit blasting steel, prime steel with zinc cold galvanising, prime and then replace concrete with a polymer modified shrinkage compensated mend mortar. In order to stop contaminants (Chloride ions and carbon dioxide) entering the concrete, a coating (Acrylics) should be applied to stop water and contaminant ingress. This is applied after the mend is carried out.

Trees
Once minor damage to homes has been caused commonly it is not viable from a financial perspective to carry out major repairs. In some instances this may happen but this is rare. If a wall has dropped from soil shrinkage the most tasteless rectification is to under pin the footing. This involves excavating under the existing footing, propping, pouring a new footing and then grouting in the middle of the new and existing footings. Under pinning is very expensive.

If trees cannot be removed a trench approx 2m deep can be dug in the middle of the house and the tree and then lined with an impermeable root fabric to stop the tree roots growing under the house.

Stormwater damage
If the gutters and downpipes are leaking they should be repaired and or replaced. In most instances these elements do not drain out to the street. If this is the case the stormwater should be diverted out to the road via stormwater pipes.

Lack of Paving.
The vital elements to control cracking in older homes is to keep the soil colse to the footing in a garage moisture range. This can be achieved by installing paving .It is leading however to water gardens consistently during summer for a fixed duration and intervals in areas adjacent to the paving. This keeps the soil moist adjacent to the paving (Best to use an electronic watering system).

Older style wiring In order to stop the occasion of an electrical fire, older wiring should be removed and substituted with new Pvc wiring together with the facility of earth leakage circuit breakers.

Leaking pipes
In order to check if existing pipes are corroding a plumber can pressure test the pipes or use a Cctv system. commonly any older steel or lead pipes should be removed and substituted with Pvc however this can be high-priced as concrete floors need to be jack hammered to passage the pipes.

Cracks in walls
Generally the best way to control movement is to say a house. This allows it to move by installing wall control joints above windows and doors and slip joints in the middle of the hard plaster and the brickwork. To form a slip joint remove render, install mesh onto bricks and replaster with a lime rich mortar. A lime rich mortar is used to sell out the cement article and hence the rigidity of the render with a 1 cement, 10 sand and 2 parts lime mortar).

In relation to soil shrinkage cracks a estimate of soil engineers in Adelaide have instigated the direct injection of water into the soil colse to the footings to the external perimeter of homes (Mainly to Parkside). This keeps the soil in a garage moisture range via the computer controlled injection of water into the soil.

Roof Frame failures
In most instances roof frame failures are easy to rectify by propping the sagged or damaged area and whether lapping the member whether side with new timber or inserting additional props (The props commonly run from the under purlin to the internal wall). In the case of gang nail failures lapped timber bolted whether side of the affected timber can also solve this defect.

White ant failures.
Ants can be prevented from entering a house via chemical sprays , Ant caps (Stumped homes) or stainless steel mesh barriers (Termimesh). If existing homes are infested, the homes can be sprayed with chemicals or have bait stations inserted settled colse to the external perimeter of the home which are actually baited with poisoned timbers (Sentricon system).

Property safe does not carry out a explore for white ants in our pre buy inspections and we would recommend that you engage a pest controller to do this.

Poor workmanship In each instance the work should be carried out as per the requirements in the Bca ie.

-Weep holes during rendering cut the render out of the weepholes
-Bricks Overhang footing Set out floor slab correctly.
-Render bridges damp procedure Cut a horizontal line in the render over the Dpc
-Concrete slab poured up against bricks Ensure that the i.e. Porch slab is poured up against the edge of the main footing.
-Puddle flanges Ensure that the flange is flush with the top of the floor. The timber/concrete needs to be rebated down to allow the flange to sit flush with the floor.
-Membrane to showers Ensure that the membrane is installed in accordance with the Bca.

E/Conclusions
The bulk of the causes of building failures as detailed in this cast study are due to changes in the moisture conditions in the soil colse to the footings due to seasonal change. The remedies discussed revolve colse to keeping the soil in a constant moisture state. The measures discussed include installing paving and electronic garden watering systems, diverting stormwater away from the house, ensuring plumbing does not leak, keeping tree roots away from footings and articulating older homes to enable them to move.

Of the remaining failures many are due to poor maintenance and or building techniques. Ie Damp Courses bridging paving (Non Bca compliant) can cause white ant infestations and or Salt damp.

base Causes For Residential construction Failures